●The input/output side is eqipped wth surge absorption circult. which can efectively prolong the service ite of relay contects end slow down the instantaneous impulse current at load side
●NPNPNP bipaler imput is competbe, and the indicator ight wll alsa light upin different colors according to the input signel. green-NPN, red- PNP:
●Wrong line protection at input side
◆ Application
Applicable to Mitsubishi, Siemens, 0mron, Panasonic and other PLC
INPUT COIL PARAMETERS
Rated voltage
5VDC/12VDC/24VDC
Rated current
7.5mA,8.3mA
Action voltage
More than 75% (room temperature environment)
Release voltage
5% or less (room temperature environment)
Action time
20ms or less
Release time
10ms or less
Contact resistance
30mΩ or less (DC6V 1A) Below 100mΩ (DC6V 1A)
Insulation resistance
1000m Ω (500VDC)
OUTPUT CONTACT PARAMETERS
●Contact material
Silver Aly
●Electrical Performance
5A/250VAC、5A/30VDC
●Mechanical durablity
5000000second
●Operating ambient temperature -40-85*C(no ice and Frost)